Ultrasonic Meter Type

Water Meter, District

uFlow 340 SERIES (DN50-600)

1. Introduction

The uFlow 340W series compact type ultrasonic water is an innovative flow meter with static flow sensor based on the ultrasonic measuring principle. It utilizes ultrasonic measuring methodology and microprocessor technology. All calculation and flow measuring circuits are designed on one single board, thus offering exceptional accuracy and reliability.

2. Features

  • Water temperature detection, low temperature alarm
  • Abnormal water usage alarm
  • Low starting flow rate, minimum flow rate is 1/3 traditional water meter
  • High-precision machining centers, initiating action to prevent the occurrence of product non-conformity, stable and reliable
  • Adaptable to inferior water quality, low in maintenance cost
  • Ultrasonic signal quality detection
  • Low initial flow rate and min. flow velocity measured is 0.002m/s
  • No mechanical moving parts, long service life
  • Ultra low power consumption, battery life of over 10 years (DN15-40) & 6 years (DN50-600); less then 0.0008W
  • Support optical, RS485 and M-BUS (wired & wireless) communication interface
  • Complies to MODBUS RTU and EN13575 communication protocol
  • IP68 design

3. Application

  • Residential water meter
  • Tenant billing

4. Dimensions

Nominal Diameter (mm) 50 65 80 100 125 150 200 250 300 350 400 500 600
Dimension (mm) L 200 200 225 250 250 300 350 450 500 500 600 600 800
L1 120 120 120 120 120 120 120 120 120 120 120 120 120
H 245 250 275 290 380 400 470 530 580 640 695 815 925
H1 65 70 90 100 125 130 170 203 230 260 290 358 420
W 123 123 123 123 123 123 123 123 123 123 123 123 123
B 172 190 205 230 250 285 340 405 460 520 580 715 840
D 165 185 200 220 250 285 340 405 460 520 580 715 840
nxФD1 4 x Ф18 8 x Ф18 8 x Ф22 12 x Ф22 12 x Ф22 16 x Ф26 16 x Ф30 20 x Ф33 20 x Ф36
Maximum flow rate Q4 (m³/ h) 31.25 50 78.75 125 200 312.5 500 787.5 1250 1250 2000 3125 5000
Nominal flow rate Q3 (m³/ h) 25 40 63 100 160 250 400 630 1000 1000 1600 2500 4000
Transitional flow rate Q2 (m³/ h) 0.1 0.16 0.252 0.4 0.64 1 1.6 2.52 4 4 6.4 10 16
Minimum flow rate Q1 (m³/ h) 0.063 0.1 0.158 0.25 0.4 0.625 1 1.575 2.5 2.5 4 6.25 10
Starting flow reference (m³/ h) 0.01 0.02 0.03 0.05 0.08 0.1 0.2 0 0.4 0.6 0.75 1.2 1.8
Pressure Loss Δp25 Δp10
Working Pressure 1.6MPa 1.0MPa
Qp:Qi 400:1 ( 100:1, 160:1, 250:1, 500:1, 800:1 can be customized)

5. Technical Specification

SPECIFICATIONS – Calculator
Display LCD, 8 digits
Instantaneous flow, Flow volume
Approval

MID

Language English
Temperature Class T30, T50, T70 optional
Power Supply 3.6V lithium battery
Battery Lifetime

≥10 years

Environment & Mechanical Condition Class C (Class B, Class I optional)
Electromagnetic Compatibility E1 (Class E2 optional)
Ambient Storage Temperature -20°C ~ +70°C
Installation Horizontal or vertical
Communication Modbus, M-bus, optical, pulse
IP Rating

IP65, IP68 (upon request)

Accuracy

Class 2

For more information, please download the full brochure here