Ultrasonic Meter Type

BTU Meter / Flow Meter, Residential

uFlow 230 SERIES

1. Introduction

The uFlow 230 series ultrasonic BTU meter can be used for measuring the energy consumption in heat / cooling application for billing purpose. The measurement principle is static and based on the measurement of transit time with pair of ultrasonic transducer propagating at each other upstream and downstream. All calculation and flow measurement circuits are designed on one circuit board, thus offering exceptional accuracy and reality.

uFlow

2. Features

  • High capacity 3.6 lithium battery inside, above 8 till 10 years shelf life
  • Dynamic range of 250:1, 100:1, 50:1
  • Can be mounted in flow pipe or return pipe, and can be mounted horizontally or vertically
  • Support optical, RS485 and wired & wireless M-bus interface, convenient for user to manage data in different manners
  • Complies to Modbus RTU and EN13757 communication protocol
  • Certified by CMC and MID
  • Advanced calibrating device, adopt international advanced automatic heat meter calibration device, ensure the product accuracy
  • Can be used as cooling, heat or combined climatic meter

3. Application

  • Green building management
  • Tenant billing
  • Energy management

4. Dimensions

Nominal Diameter (mm) 15 20 20 15 20 20 20 20 25 25 32 40
Nominal Flow Rate (m³/h) 0.6 0.6 0.6 1.5 1.5 1.5 2.5 2.5 3.5 6 6 10
Dimension Body Length, L 110 130 190 110 130 190 130 190 160 260 180/260 200/300
Overall Length, L 200 230 290 200 230 290 230 290 260 360 280/360 300/400
Calculator Length, L1 150 150 150 150 150 150 150 150 150 150 150 150
Height, H 100 103 103 100 103 103 103 103 106 106 109 113
Calculator Height, H1 60 60 60 60 60 60 60 60 60 60 60 60
Calculator Breadth, B 105 105 105 105 105 105 105 105 105 105 105 105
Screw Thread G3 / 4B G1B G1B G3 / 4B G1B G1B G1B G1B G1 / 4B G1 1/4B G1 1/2B G2B
Screw Thread Coupling R1/2 R3/4 R3/4 R1/2 R3/4 R3/4 R3/4 R3/4 R1 R1 R1 1/4 R1 1/2
Working Pressure 1.6MPa (2.5MPa can be customized upon request)
Qp:Qi 50:1, 100:1, 250:1

5. Technical Specification

SPECIFICATIONS – Calculator
Display

LCD, 8 digits

Energy, power, volume, temperature, flow rate

Cummulative heat energy: KWh or MJ (display range: 0~9999999.9), Thermal power: KW
Instantaneous flow: m³/h, cumulative volume:m³, Supply water temperature: °C. Return water temperature: °C, Temperature difference, Total operating time
Approval

MID

Language English
Ambient Storage Temperature

A Class (5~55) °C or B Class (-25~55)°C optional

Temperature Measuring Range

4-95°C, 130°C can be customized

Temperature Sensor

PT1000 (PT500, PT100 can be customized)

Cable Length of Temperature Sensor

1.3 meters

Power Supply

3.6V lithium battery

Battery Lifetime

≥10 years

Installation

Horizontal or vertical

Communication

Modbus, M-bus, optical, pulse

IP Rating

IP67

Accuracy

Class 2

Mounting Position

Vertical or horizontal

 

TECHNICAL PARAMETER
Flow Velocity

0.1 ~ 7m/s

0.15~12m/s (need to be customized)

Maximum Volume

999999.99

Maximum Heat

999999999

For more information, please download the full brochure here