Electromagnetic Heat Energy Measurement (BTU) Meter

eFlow 900H SERIES

1. Introduction

The eFlow 900H series electromagnetic heat meter is a high performance smart meter that features the latest technology. Design structure, manufacturing process, testing & etc are controlled to ensure product’s quality like high accuracy, good performance, wide range and etc. The eFlow 900 will not fail over time as there are no moving parts, therefore, maintenance-free. Furthermore, eFlow 900 uses electromagnetic field technology to measure the flow’s medium. This allows the eFlow 900 to perform well regardless of the quality of liquid.

2. Features

  • Accuracy: ± 0.5% of flow rate for ( >DN3 )
  • Excellent & accurate small flow measurement
  • Pipe connection: JIS 10K, JIS 20K, ANSI 150, ANSI 300, DIN PN10, DIN PN16
  • Cold, heat energy measurement
  • Build-in ground electrode, grounding ring not needed
  • Designed according to PED Directive 97/23 EC
  • Double frequency excitation, stable zero point

3. Application

  • District heat / cooling
  • Energy Management
  • Green energy management
  • HVAC
electromagnetic-flow-meter-schematic

4. Technical Specification

SPECIFICATIONS – Calculator
Display Heat energy, Supply & Return Temperature, Instantaneous flow alarm display, percentage, velocity, forward and reverse integrated flow and
total integrated flow
Blackout data protection Data will be stored by EEPROM without backup battery
Language English
Low-frequency square wave exciting 1/16 power frequency, 1/20 power frequency, 1/25 power frequency
High-frequency square wave exciting ½ power power frequency
Exciting Current 125mA, 187.5mA, 250mA, 500mA
Speed Range 0.1 – 15m/s
Speed Resolution 0.5mm/s
Ambient Temperature Range -10°C ~ +60°C
Relative Humidity 5%~90%
Communication MODBUS, GPRS, PROFIBUS, HART
Power Supply 24VDC, 240VAC
IP Rating IP65, IP68 (upon request)
Accuracy ±0.5%, ±0.3
Power Rating < 20W ( After connecting sensor )
SPECIFICATIONS – Flange
Nominal Diameter

DN15 ~ DN3000

Nominal Pressure

0.5~4MPa ( special pressure can be made upon request)

Accuracy

±0.5%, ±0.3% or ±0.2% are selectable

Linear Material

Teflon, pfa, f46, Neoprene, Poly

Electrode Type

General type, Scraper type and replaceable type

Electrode Material

Stainless stell SU316, Hastelloy C, Titanium, Tantalum Platinumiridium, etc

Ambient Temperature

-25°C ~ +60°C

Ambient Humidity

5~100%RH (relative humidity)

Measuring Range

1500:1, <15m/s

Structure Type

Integral type, remote type, submersible type, ex-proof type

Protection Class

IP65, IP68 (optional)

Ex-proof

Exmd II T4

Production Standard

JB/T 9248-1999 Electromagnetic Flowmeter

For more information, please download the full brochure here